Timers
MICON 175
Features :-
- Compact 17.5mm Wide
- Integrated Dual Voltage
- Functions: ON Delay, Star Delta, One Shot
- Wide Time Range: 0.1 - 100 hours
- LED Indications for Power and Relay status
- Low Power Consumption
MICON 225
Features :-
- Multi-function with Signal Start and Supply Start.
- 16 Timing Functions selected by DIP switch.
- Two independent relay outputs with either both relays timed or one timed and one instantaneous.
- Wide Input Signal & Supply range - 24-240V AC/DC.
- Wide Timing Range - 0.1 s to 120 days.
- High timing Accuracy.
- LED indicators for Power Supply & Relay Status.
- 22.5mm DIN Mount Housing.
Digital Timer DIGICON
Features :-
- Compact 17.5 mm Wide
- Multi Function: (8 or 18) Non Signal & Signal based functions
- Multi-Voltage: 24 - 240 VAC/DC
- Wide Timing Range: 0.1s to 999 Hr
- 3 Digit LCD for Preset time and Run time
- Option to select Up/Down counting
- Tamper proof with key lock feature
Motor Restart Timer
Features :-
- Compact 17.5mm wide
- Brown Out Timer with 2 Functions: ON Delay, Interval
- Detects Voltage Dips and Momentary Loss of Supply & Resets the control panel
- Low Power Consumption
- Fast Response Time
- LED indications for Healthy & Unhealthy conditions
- Excellent Noise Immunity to the latest IEC standards
Time Switches
FM1 / Quartz
Product Description |
Cat No. |
FM1 / Quartz Daily |
240 VAC Base/DIN Mounting |
J648B1 |
110 VAC Base/DIN Mounting |
J638B1 |
240 VAC Flush Mounting |
J648F1 |
110 VAC Flush Mounting |
J638F1 |
FM1 / Quartz Weekly |
240 VAC Base/DIN Mounting |
J848B1 |
110 VAC Base/DIN Mounting |
J838B1 |
240 VAC Flush Mounting |
J848F1 |
110 VAC Flush Mounting |
J838F1 |
Digital Time Switch
Product Description |
Cat No. |
Time Switch (Crono) |
110 - 240 VAC 1 C/O Base/DIN 25 ON/OFF |
67DDT0 |
24 VDC 1 C/O Base/DIN 25 ON/OFF |
6GHDT0 |
12 VDC 1 C/O Base/DIN 25 ON/OFF |
69HDT0 |
Time Switch (Pulse) |
110 - 240 VAC 1 C/O Base/DIN 16 Pulse |
67DDT9 |
24V DC 1 C/O Base /Din 16 Pulse |
6GHDT9 |
12V DC 1 C/O Base /Din 16 Pulse |
69HDT9 |
Astro Mini
Product Description |
Cat No. |
Time Switch (Astro Mini) 110 - 240 VAC 1 Phase - 2W, 1 C/O, Base/DIN |
T2DDT7 |
Astro
Product Description |
Cat No. |
Time Switch (Astro) |
110 - 240 VAC 1 Phase - 2W 2 Channel 2NO, Base/DIN |
T2DDT0 |
110 - 240 VAC 3 Phase - 4W 3 Channel 3NO, Base/DIN |
T3DDT0 |
Accessories |
Software on PC for Astro |
TGDDT6 |
USB Interface Cable |
GFDNN1 |
Memory Card for Astro |
GFDNN3M |
3 Phase Astro Accessories |
Surge Suppressor |
19D2000C |
Astro GSM Module (GSM - ERT5), Remote Side |
19D20B00 |
Communication Cable (TTL - TTL) between Astro & GSM Module |
19A1000B |
Supply Monitoring Devices
Voltage Monitoring
Voltage Monitoring Series SM 175
Features :-
- Compact 17.5 mm wide
- Protects against Phase Loss, Phase Reversal & Phase Asymmetry
- Multi-voltage from 3 x 208 to 3 x 480 V
- Selectable Under voltage / Over voltage / Asymmetry levels
- Selectable Under Voltage / Over Voltage & Asymmetry
- LED indication for all faults & for change in settings during run time for better security
- Adjustable time delay
Voltage Monitoring Series SM 301
Features :-
- Protects against Phase Loss, Phase Reversal and Phase-Phase Unbalance
- No auxillary supply needed
- Voltage sensing principle
- 1 C/O & 2 C/O Configurations
- Designed to meet Industrial and Agricultural segment applications
Supply Monitoring Series SM 500
Features :-
- Protects against Phase Loss, Phase Reversal and Phase-Phase Unbalance
- Can be configured for 3 Phase 4 Wire or 1 Phase system
- Selectable Over/Under voltage trip level
- Selectable Time Delay
- LED indications for power and fault conditions
- Voltage sensing principle
- 1 C/O or 2 C/O Configuration
Voltage Monitoring Series SM 501
Features :-
- Protects against Phase Loss, Phase Reversal and Phase-Phase Unbalance
- Suitable for 3 Phase 3 Wire system
- Selectable Under Voltage / Ovder Voltage Trip level
- Selectable Time Delay
- Models for Selectable Phase Asymmetry
- LED indications for power and fault conditions
- Voltage sensing principle
Frequency Monitoring
Frequency Monitoring Series PD 225
Features :-
- Wide Auxiliary Supply voltage Range: 110 - 240 VAC, 220 - 440 VAC
- Models for Over Frequency and Under/Over Frequency Monitoring
- Monitors frequency of three signals - Sine, Square & Triangular
- Model for Frequency Limit Control: 5 Hz to 135 Hz
- Wide Signal Input Voltage: 15 to 500 VAC
- Ease of Frequency setting with simple Addition & Subtraction
- LED indications for healthy, unhealthy & no signal conditions
Earth Leakage Ralay
Earth Leakage Relay Series CMR
Features :-
- Monitors, Detects and Protects Power systems from Leakage faults
- Wide Auxiliary Supply range: 110 - 240 VAC, 220 - 415 VAC
- Wide Range of selectable Earth Leakage Current: 60 mA - 300 mA, 0.2A - 1.2A
- Configurable Earth Leakage Trip time: 100 ms - 5 s
- Easily configurable operating modes
- Test feature to check complete product functionality
- Manual / Remote reset feature
- LED indication for Relay status, CT open, Earth leakage fault & Test/Reset switch feature
Earth Leakage Relay 30MA-30A
Features :-
- Monitors, Detects and Protects Power systems from Earth Leakage Faults
- Wide range of selectable Earth Leakage Current: 30 mA - 30 A
- Configurable Earth Leakage Trip time: 0 - 10 s
- Wide Auxiliary Supply Range: 110 - 240 V AC / 110 V DC, 220 - 415 V AC / 220 V DC
- Instantaneous Trip for 5 times of set value of Leakage current
- Test feature to check complete product functionality
- LED Indication for Relay status, CT open, Earth Leakage fault & Test/Reset switch feature
- Manual / Remote Reset feature
- 1 C/O + 1 NO Relay Output
Current Monitoring
Current Monitoring Relay
Features :-
- Protection against Overload, Phase Loss, Phase Reverse and Phase Unbalance faults
- Wide range of sensing current : 1A - 45A
- Models for 1 Phase and 3 Phase systems
- Auto / Manual Reset selection
- Fail - safe protection
- Inverse time model with underload, locked rotor protection and selectable trip class
- Definite time model with underload and selectable start and trip time
Hour Meter & Counter
Hour Meters
Features :-
- Protection against Overload, Phase Loss, Phase Reverse and Phase Unbalance faults
- Wide range of sensing current : 1A - 45A
- Models for 1 Phase and 3 Phase systems
- Auto / Manual Reset selection
- Fail - safe protection
- Inverse time model with underload, locked rotor protection and selectable trip class
- Definite time model with underload and selectable start and trip time